Analab Scientific Instruments Private Limited

Analab Scientific Instruments Private Limited

Email
Send Email

Melting/Boiling Point Apparatus

Analab Scientific Instruments Private Limited

Home  » Products  » Melting/Boiling Point Apparatus  » Programmable Automatic Melting / Boiling Point Apparatus

Programmable Automatic Melting / Boiling Point Apparatus

The Programmable Automatic Melting/Boiling Point Apparatus (Model: µThermoCal25) is used in chemical, iron, steel, textile and various others industries for determining the melting point of solids and boiling point of liquids. The apparatus is available with power cord, Teflon coated magnetic paddle, operational & instruction manual, boiling tube, silicon oil, heater, RTD sensor, Teflon assembly for holding capillary, 250ml beaker and Melting Capillary one end sealed (Pack of 100 Nos).

Model : µThermoCal25

Supplied with 250ml Beaker, Teflon Assembly for holding capillary, Heater, RTD Sensor, Silicon Oil, Melting Capillary one end sealed (Pack of 100 Nos), Boiling Tube, Teflon Coated Magnetic Paddle, Power Cord, Operational & Instruction Manual.

Salient Feature

  • Built in Magnetic Stirrer with soft touch Key Speed Controller with audio sound.
  • Automatic Temperature Heating depending upon heating requirement.
  • Electronic Temperature Regulator to increase / decrease heating rate.
  • Facility to enter set temperature by using soft touch keypad.
  • Soft Touch Keypad to prevent contact problem.
  • Over heating protection by heater cut-off.
  • On-site Temperature Calibration by Calibrated Thermometer / Calibration standards.
  • Re-Call Default factory set calibrated temperature data.

Technical Specification

Temperature Range 5ºC Above Ambient to 300ºC
Heating before set point Automatic Temperature Heating depending upon temp. diff.
Heating after Set point Variable 0.5, 1.0 & 2.0 ºC/min - Selectable
Detection of Melting Melting Range
Temperature Resolution 0.1ºC
Calibration Multipoint Point Calibration Standard - as per Pharmacopia or any users known standard.
Melting Capillary Three Capillary
Sample Borosilicate Capillary Tube One End Sealed
a) OD 1.4 to 1.6 mm b) ID : 1.0mm c) Filling Height : 3 mm
Temperature Sensor PT-100
Data Storage Non Volatile Memory with more than 50 analysis data storage with corresponding calibration data.
Method Storage Ten User method parameter with Add/Edit Facility.
Printer Output Parallel Port (Optional)
Keyboard Alphanumeric Polyester Softkeys
Backlit LCD Display 20 x 4 Line Alphanumeric
Power 230 VAC ± 10%, 50Hz

Optional

  • Camera attachment
  • Parallel Port for Dot matrix Printer attachment
  • RS-232 to USB Interface with Cable & Driver Software to Transfer Data From Inst. to PC


Yes! I am Interested


Looking for Product Name ?

x

Send SMS Enquiry

*Please Enter Requirment

*Please Enter valid Mobile Number

*Please Enter Proper Name