Product Details:
| Usage/Application | Laboratory Use |
| Brand | Analab |
| Model Name/Number | ConCal+ |
| Power Supply | DC Adaptor |
| Country of Origin | Made in India |
| Display Type | 16x2 Line Alphanumeric Backlit LCD |
Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Instruction & Operational Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.
Product Details:
| Usage/Application | Laboratory |
| Model Name/Number | ConCal10+ |
| Brand | ANALAB |
| Resolution | 1 PPM |
| Country of Origin | Made in India |
| Power Supply | DC Adaptor |
Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.
Product Details:
| Type Of Ph Meter | Hand-Held |
| Usage/Application | Laboratory |
| Model Name/Number | pHCalHandheld |
| Brand | ANALAB |
| Display Type | 16 x 2 Line Alphanumeric Backlit LCD |
| Calibration | Two Point Calibration |
| Ph Range | -1.000 to 15.000 pH |
| Temperature Range | -5.0 to 130.0 degree celsius |
| Power Supply | Rechargeable Battery with Charger |
Supplied with Combination Glass pH Electrode (0-70ºC), Temperature Probe, Carrying Case, Standard Buffer Tablets (7.00 pH, 4.01 pH & 9.18 pH), Bottles for Standard Buffer, Rechargeable Battery, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.
(Supplied without Electrode Stand)
Technical Specification:
pH
Range: -1.000 to 15.000 pH
Selectable Resolution: 0.01 pH
Relative Accuracy: ± 0.02 pH
mV / ORP
Range – mV / RmV: ± 2000.0
ORP: EH auto calibration to standard hydrogen electrode
Resolution: 0.1
Relative Accuracy: ± 0.2 mV OR 0.05%, whichever is greater.
Temperature
Range: -5.0 to 130.0ºC
Resolution: 0.1°C
Relative Accuracy: ± 0.1ºC
Temperature Compensation: Auto / Manual
Temperature Calibration: In-built software and can be calibrated by users
Slope: 80-120 %
Auto Buffer Recognition: 7.00, 4.01 / 9.18 pH @25ºC for Two points.
Display Reading: Simultaneous - pH, mV & Temperature.
Buffer Standard: US / NIST & EURO
Error Messages: “Bad Buffer / Electrode”, “Temperature Probe Error”, “Low Memory” & “pH Over Range”.
Short Link: Provided to diagnose the problem either with Instrument OR Electrode.
Display: 16 x 2 Line Alphanumeric Backlit LCD
Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
Calibration Data Storage: Non-Volatile Memory which can store & view calibration date & time, calibration point, pH, mV, temperature, % slope etc.
Special Features: Auto Power Off, Backlit On / Off for battery conservation.
Power Supply: Rechargeable Battery with Charger
Product Details:
| Material | Mild Steel |
| Conductivity Range | 150 mS/cm |
| Usage/Application | Laboratory |
| Brand | ANALAB |
| Country of Origin | Made in India |
| Power Supply | DC Adaptor |
| Model | ConCal50 |
Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, ANALABsafe software, USB Interface Cable, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.
Product Details:
| Model Name/Number | pHCal50 |
| Usage/Application | Laboratory Use |
| Brand | ANALAB |
| Calibration | Three / Five Point Calibration |
| Display Type | 20 x 4 Line Alphanumeric Backlit LCD |
| Country of Origin | Made in India |
| pH Range | -2 to 20 pH |
| pH Resolution | 0.01 pH |
| Temperature | -5 to 130 Degree Celsius |
| Power Supply | DC Adaptor |
Supplied with Combination Glass pH Electrode (0-70°C), Standard Buffer Tablets (7.00 pH, 4.01 pH & 9.18 pH), Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Operational & Instruction Manual, Manufacturer Test Certificate and Warranty Card.
Product Details:
| Brand | ANALAB |
| Type Of Ph Meter | Hand-Held |
| Usage/Application | Laboratory Use |
| Model Name/Number | ConCalHandheld |
| Display Type | 16 x 2 Line Alphanumeric Backlit LCD |
| Country of Origin | Made in India |
| Temperature Range | 0.0 to 130.0 Degree Celsius |
| Temperature Resolution | 0.1 Degree Celsius |
| Power Supply | Rechargeable Battery with Charger |
| Temp. Compensation | Auto / Manual |
Supplied with Conductivity Cell K=1.0 with Connector, Temperature Probe, Carrying Case, Rechargeable Battery, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card. (Supplied without Electrode Stand)
Technical Specification:
Conductivity Range : 0 - 20.00, 20 - 200.0, 200 - 2000µS/cm², 2 - 20.000, 20 - 200 mS/cm²
Conductivity Resolution : 0.001, 0.01, 0.1 µS/cm² & 0.001, 0.01 mS/cm²
TDS Range : 0 to 10, 100, 1000, 10000, 100000 ppm
TDS Resolution : 0.001, 0.01, 0.1 ppm & 0.001, 0.01 ppt (1ppt=1000ppm)
Temperature Range : 0.0 to 130.0°C
Temperature Resolution : 0.1°C
Temperature Compensation : Auto / Manual
Temperature Coefficient : 0-10.000 % per °C (Adjustable)
Temperature Calibration : In-built software and can be calibrated by users
Number of Range : One
Calibration Standard : One
Calibration Factor : One
Suitable Cell Constant : 1.0 & 0.1 K
Adjustable Cell Constant : 0.90 to 1.1 K
Conductivity to TDS Conversion : 0.40000 to 1.00000 (Adjustable Factor)
Reading : Conductivity at actual temperature and at 25°C and TDS with scrolling Display.
Error Messages : “Wrong Standard / Cell”, “Cell Short”, “Cell Open”, “Try Upper Range”, “Try Lower Range” & “Temperature Probe Error”.
Display : 16 x 2 Line Alphanumeric Backlit LCD
Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
Calibration Data Storage: Non-Volatile Memory which can store & view calibration cell constant, calibration range, standard conductivity solution, measured conductivity at 25°C, actual temperature, calibration factor etc.
Special Features : Auto Power Off, Backlit On / Off for battery conservation.
Power Supply : Rechargeable Battery with Charger
Product Details:
| Conductivity Range | 150 mS/cm |
| Usage/Application | Laboratory |
| Brand | ANALAB |
| Model Name/Number | ConCal5+ |
| Country of Origin | Made in India |
| Power Supply | DC Adaptor |
Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.
Product Details:
| Minimum Order Quantity | 01 Piece |
| Display | 20 x 4 Line Alphanumeric LCD with Backlit |
| Model Name/Number | FlameCal50 |
| Brand | Analab |
| Detector | Silicon Photodiode |
| Range | 15-100 ppm |
| Automation Grade | Automatic |
| Flame System | LPG Dry Oil Free |
| Usage/ Application | For Laboratory |
| Power Supply | 230 V AC |
| Air Gas Control | Adjustable with Knob |
Product Details:
| Minimum Order Quantity | 01 Piece |
| Type Of Ph Meter | Hand-Held |
| Usage/Application | Laboratory |
| Resolution | 0.01 pH |
| Brand | ANALAB |
| Model Name/Number | EC 035 |
| Calibration | Two / Three Point Calibration |
| Display Type | 16 X 2-line Alphanumeric Display |
| Ph Range | 0-14 pH |
| Is It Water Proof | Non Water Proof |
| Power | Rechargeable Battery with Charger |
| Material | ABS |
| Atc Ph | Auto Compensation |
| Slope Correction | 80-100 |
| Ph Electrode | Glass / Epoxy |
| Voltage | 12VDC |
| Warranty | 12 Month against any manufacturing Defects. |
| Battery Type | AA Rechargeable Batteries |
| Cal. Points | 2/3 |
| Compensation | Auto / Manual |
| Range | 0-14 pH |
| Temperature Compensation | Auto / Manual |
| Country of Origin | Made in India |
Supplied with Combination Glass pH Electrode (0-70ºC), Conductivity Cell K=1.0, Standard Buffer Tablets, Temperature Probe, Electrode Stand consists of Clamp, Dust Cover, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.
Additional Information:
Product Details:
| Model Name/Number | pHCal5+ |
| Type of PH Meter | Table-Top |
| Usage/Application | Laboratory |
| Calibration | Two/Three Point Calibration |
| Display Type | 16 x 2 Line Alphanumeric Backlit LCD |
| Brand | ANALAB |
| Ph Range | -1.00 to 15.00 pH |
| Slope Correction | 80-120% |
| Country of Origin | Made in India |
| pH Resolution | 0.01 pH |
| Temperature | 0 to 100 Degree Celsius |
Supplied with Combination Glass pH Electrode (0-70ºC), Standard Buffer Tablets (7.00 pH, 4.01 pH & 9.18 pH), Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.
Technical Specification:
pH Range : -1.00 to 15.00 pH
pH Resolution : 0.01 pH
pH Relative Accuracy : ± 0.02 pH
mV / Accuracy : ± 2000.0 mV / 0.2mV OR ± 0.05% of reading whichever is greater.
Temperature
Temperature Range : 0 to 130.0ºC
Relative Accuracy : ± 0.1ºC
Temperature Compensation : Auto / Manual
Temperature Calibration : In-built software and can be calibrated by users
Slope : 80-120 %
Total Numbers of Slope : 1 slope for Two-point calibration & 2 slopes for Three-point calibration.
Auto Buffer Recognition : 1) 7.00, 4.01/9.18 pH @25ºC for Two points
2) 4.01, 7.00, 9.18 / 10.01 pH @25ºC for Three points
Display Reading : Simultaneous - pH, mV & Temperature.
Buffer Standard : US / NIST & EURO
Error Messages : “Bad Buffer / Electrode”, “Temperature Probe Error”, “In-complete Calibration” & “pH Over Range”.
Short Link : Provided to diagnose the problem either with Instrument OR Electrode
Display : 16 x 2 Line Alphanumeric Backlit LCD
Keypad : Membrane waterproof polycarbonate soft keypad compliance to UL/ROHS
Power Supply : DC Adaptor
Product Details:
| Type Of Ph Meter | Table-Top |
| Usage/Application | Laboratory Use |
| Model Name/Number | pHCal5 |
| Brand | ANALAB |
| Calibration | Two Point Calibration |
| Display Type | 16 x 2 Line Alphanumeric Backlit LCD |
| Country of Origin | Made in India |
| pH Range | -1.00 to 15.00 pH |
| pH Resolution | 0.01 pH |
| Slope | 80-120 % |
| Temperature | 0 to 130.0 degree celsius |
| Power Supply | DC Adaptor |
Supplied with Combination Glass pH Electrode (0-70ºC), Standard Buffer Tablets (7.00 pH, 4.01 pH & 9.18 pH), Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.
Technical Specification:
|
pH Range |
: -1.00 to 15.00 pH |
|
pH Resolution |
: 0.01 pH |
|
pH Relative Accuracy |
: ± 0.02 pH |
|
mV / Accuracy |
: ± 2000.0 mV / 0.2mV OR ± 0.05% of reading whichever is greater. |
|
|
|
|
Temperature |
|
|
Temperature Range |
: 0 to 130.0ºC |
|
Temperature Accuracy |
: ± 0.1ºC |
|
Temperature Compensation |
: Auto / Manual |
|
Temperature Calibration |
: In-built software and can be calibrated by users |
|
Slope |
: 80-120 % |
|
Auto Buffer Recognition |
: 7.00, 4.01 / 9.18 @ 25ºC |
|
Display Reading |
: Simultaneous - pH, mV & Temperature. |
|
Error Messages |
: “Bad Buffer / Electrode”, “In-complete Calibration” & “pH Over Range”. |
|
Short Link |
: Provided to diagnose the problem either with Instrument OR Electrode |
| Display |
: 16 x 2 Line Alphanumeric Backlit LCD |
|
Keypad |
: Membrane waterproof polycarbonate soft keypad compliance to UL/ROHS |
|
Power Supply |
: DC Adaptor |
Product Details:
| Model Name/Number | MultiCal10 |
| Brand | ANALAB |
| Usage/Application | Laboratory |
| Cell Constant | 0.1, 0.5 & 1.0 K |
| Power | DC Adaptor |
| Country of Origin | Made in India |
Supplied with Combination Glass pH Electrode (0-70ºC), Conductivity Cell K=1.0, Standard Buffer Tablets, Temperature Probe, Electrode Stand consists of Clamp, Dust Cover, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.